APC RACK PDU 2G
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
Brand APC Shipping Dimension (DxH) 16.51 x 8.89 cm Capacity 220…240 V Input Voltage 200 V , 208 V , 230 V Output Voltage number of power socket outlets : 21 IEC 60320 C13 , 3 IEC 60320 C19 Temperature -5…45 °C ; ambient air temperature for storage : -25…65 °C Relative Humidity 5…95 % ; Storage altitude : 0.00…15240.00 m Feature 01 High density 2U, 6-in (150-mm) deep, horizontal cable manager with cover. Features cable access slots with pre-installed brush strips in the backplate for front to back cable pass-through and a bottom plate with features for additional cable tie-off and routing. 120,000.00৳ -
APC SURGE PROTECTOR FOR,NOTEBOOK
APC PNOTEPRO3 Surge Arrest Notebook Pro Surge Protector (Discontinued by Manufacturer)
Product Type Power Protection Brand APC Shipping Dimension 4.88 x 1.5 x 1.2 inches Body Color Charcoal Temperature -15 – 45 °C Relative Humidity 0 – 95 % Feature 01 Receptacle Style: IEC 320-C6 Feature 02 Surge energy rating: 180Joules Feature 03 ts_nm_surge_response: 1ns Feature 04 Peak Current Normal Mode: 6.5kAmps Weight 4 ounces 1,500.00৳ -
Apc powER DrsrRrBUTroN uNtr,2c swtrcH zERo u
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding.
Product Type Power Distribution Brand APC Input Connection IEC 60309 32 A 2P + E Output Connection (21) IEC 60320 C13 (3) IEC 60320 C19 Input Voltage 220 – 240VAC Output Voltage 220 – 240VAC Frequency 50/60 Hz Load Capacity 7400VA Max Input Current 32 Body Color Black Temperature Opening: -5 – 60 °C, Storage: -25 – 65 °C Feature 01 Units per Pallet : 48.0 Feature 02 Number of Power Cords : 1 Feature 03 plug standard: IEC 60309 32 A 2P + E Feature 04 depth: 4.6 cm Feature 05 height: 182.9 cm 48,000.00৳ -
APC NETSHELTER SX 42U 750MM WIDE X 1200MM DEEP ENCLOSURE
NetShelter SX 42U 750mm Wide x 1200mm Deep Enclosure with Sides Black Wide enclosure with increased cable management options for high density server and networking applications. 42U height to easily roll through doorways. Includes: Baying hardware, Key(s), Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels
Product Type Deep Enclosure Brand APC Shipping Dimension (HxWxD) 2118 x 851 x 1334 mm Rack Dimension Rack Width 19″ Capacity 42U Temperature Protection Class IP 20 Relative Humidity China RoHS Approvals UL 2416, UL 60950-1 Mounting Maximum Mounting Depth : 1048.0mm, 104.8CM ; Minimum Mounting Depth : 10.31inches Feature 01 Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19″ equipment. The “Fits Like a Glove” money back guarantee provides peace of mind that all of your EIA-310-E compliant rack-mount equipment will physically fit in a NetShelter. Feature 02 NetShelter SX enclosures are optimized for use with high capacity cable management systems that attach to equipment mounting rails inside enclosures aligning with equipment mounting u-spaces and provide channels for routing and managing cabling. Feature 03 Compatible with a variety of Schneider Electric rack accessory products to provide the ability to create a complete rack system. Configure rack solutions using industry leading Schneider Electric Design Portal – Small IT Solution Designer configurator complete with verification of product compatibility and useful 3rd party equipment catalog to aid in visualizing your ideal rack solution. Feature 04 Schneider Electric cooling, power distribution, and cable management products work seamlessly with IT enclosures to provide a complete infrastructure support system. Included Accessories Baying hardware, Key(s), Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels 190,000.00৳ -
APC Rack PDU 2G, Switched, ZeroU, 32A, 230V, (21) C13 (3) C19
Product Type Power Distribution Unit Brand APC Country of Origin USA Rack Dimension HxWxD : 1829mm, 182.9CM; 56mm, 5.6CM; 46mm, 4.6CM Capacity 32Amp Input Connection IEC 309 32A 2P+E Output Connection (3) IEC 320 C19 (Battery Backup), (21) IEC 320 C13 (Battery Backup) Input Voltage Nominal: 200V , 208V , 230V; Acceptable: 220-240VAC Frequency Input: 50/60 Hz Power Cable Length 3.05 meters; Power Cord: 1 Body Color Black Temperature Operating: -5 – 45 °C; Storage: -25 – 65 °C Relative Humidity 5 – 95 % Certification RoHS: Compliant; REACH: Contains No SVHCs; Battery Directive: Compliant; Battery Notes: “ts_Battery_Notes” Approvals EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE Feature 01 Overload Protection Feature 02 Alarm Thresholds: Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Feature 03 Local Current Monitoring Display: The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. Feature 04 Remote Management Capabilities: Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Feature 05 Power Delays: Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Feature 06 Remote Individual Outlet Control: Remotely manage outlets so users can turn outlets off that are not in use prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Feature 07 Rack-Mountable: Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most-in the racks near the equipment. Feature 08 Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. Weight 7.59 KG Warranty 1 Year -
APC Rack PDU 2G, Metered, ZeroU, 32A, 230V
The American Power Conversion Basic Rack PDU distributes power to devices in the rack. The Rack PDU has twenty IEC-320-C13 outlets, and four IEC-320-C19 outlets. Power cord. The 10-foot (3.05-meter) power cord terminates with IEC-309 32 A connector.
Product Type Power Distribution Unit Brand APC Country of Origin USA Rack Dimension HxWxD : 1791mm, 179.1CM; 56mm, 5.6CM; 44mm, 4.4CM Capacity 32 Amp Output Connection (4) IEC 320 C19 (Battery Backup), (20) IEC 320 C13 (Battery Backup) Input Voltage Nominal : 200V , 208V , 230V; Acceptable: 220-240VAC Output Voltage Nominal: 230 V Frequency Input: 50/60 Hz Power Cable Length 3 meters; power Cords: 1 Body Color Black Temperature Operating : -5 – 45 °C; Storage:-25 – 65 °C Relative Humidity 5-95% Certification RoHS: Compliant; REACH REACH: Contains No SVHCs; Battery Directive: Compliant; Battery Notes:”ts_Battery_Notes” Approvals IEC 60950, VDE Mounting Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment. Feature 01 Flash Upgradeable: “Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)” Feature 02 Local Current Monitoring Display: The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) Feature 03 Remote Management Capabilities: Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Feature 04 Integrates with StruxureWare Data Center Expert:”An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure Feature 05 Agility: Allows additional run time to be quickly added as needed. Feature 06 Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. Feature 07 Load indicator LED:”Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.” Feature 08 Single input power source: Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. Weight 6.93 KG Warranty 1 Year -
APC Rack PDU, Basic, Zero U, 32A, 230V, (20)C13 & (4)C19
The American Power Conversion Basic Rack PDU distributes power to devices in the rack. The Rack PDU has twenty IEC-320-C13 outlets, and four IEC-320-C19 outlets. The 10-foot (3.05-meter) power cord terminates with a IEC-309 32 A connector.
Product Type Power Distribution Unit Brand APC Country of Origin USA Rack Dimension HxWxD: 1619mm, 161.9CM; 56mm, 5.6CM; 44mm, 4.4CM Capacity 32Amp Input Connection IEC 309 32A 2P+E Output Connection (4) IEC 320 C19 (Battery Backup), (20) IEC 320 C13 (Battery Backup) Input Voltage Nominal: 200V , 208V , 230V Output Voltage Nominal: 230V Frequency Input: 47-63 Hz Power Cable Length 3.05 meters; Power Cords: 1 Load Capacity 7360 VA Body Color Black Temperature Operating:0 – 95 %; Storage:-25 – 65 °C Relative Humidity Operating & Storgae :0-95 %; Certification RoHS: Compliant; REACH: Contains No SVHCs; Other Environmental Compliance: China RoHS Approvals CE, VDE Feature 01 Resettable circuit breakers: Enables a quick recovery from overload events. Feature 02 Toolless Rack Mounting Capabilities: Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.” Feature 03 Vertical Mounting Capabilities: Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures. Feature 04 Low Cost Power Distribution: Provides a number of outlets to bring power to rack equipment at an affordable price. Feature 05 Agility: Allows additional run time to be quickly added as needed. Feature 06 Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. Weight 5.57 KG Warranty 1 Year -
APC Rack PDU,Basic,ZeroU,16A,230V,(20)C13 & (4)C19; IEC309
Product Type Power Distribution Unit Brand APC Country of Origin USA Rack Dimension HxWxD : 1619mm, 161.9CM X 56mm, 5.6CM; 44mm, 4.4CM Capacity 32 AMP Input Connection IEC 309 32A 2P+E Output Connection (4) IEC 320 C19 (Battery Backup), (20) IEC 320 C13 (Battery Backup) Input Voltage 200V , 208V , 230V Output Voltage 230 V Frequency Input: 47-63 Hz Power Cable Length 3.05 meters; Power Cord: 1 Load Capacity 7360 VA Max Input Current 32 A Body Color Black Temperature Operating Temperature: 0-45 °C; Operating Elevation: 0-3000meters; Storage Temperature: (-25-65 °C) Relative Humidity 0 – 95 % Certification RoHS: Compliant; REACH: Contains No SVHCs; Other Environmental Compliance: China RoHS Approvals CE, VDE Feature 01 Resettable circuit breakers: Enables a quick recovery from overload events. Feature 02 Toolless Rack Mounting Capabilities: Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units of the enclosure. Feature 03 Vertical Mounting Capabilities: Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures. Feature 04 Low Cost Power Distribution: Provides a number of outlets to bring power to rack equipment at an affordable price. Feature 05 Agility: Allows additional run time to be quickly added as needed Feature 06 Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. Weight 5.57 KG Warranty 1 year -
APC Rack PDU, Basic, Zero U, 10A,230V, (15)C13
The APC by Schneider Electric Rack Power Distribution Unit (PDU) distributes power to devices in the rack. The PDU has fifteen (15) IEC-320-C13 outlets. The 6.5-foot (1.98-meter) power cord terminates with a IEC-320-C14 plug.
Product Type Power Distribution Unit Brand APC Country of Origin USA Rack Dimension HxWxD : 610m , 61.0CM; 44mm, 4.4CM; 44mm, 4.4CM Capacity 10 Amp Input Connection IEC-320 C14 Output Connection (15) IEC 320 C13 (Battery Backup) Input Voltage Nominal: 120V , 200V , 208V , 230V , 240V; Acceptable: 100-240 VAC Output Voltage Nominal: 208V, 230V Frequency Input: 50/60 Hz Power Cable Length 1.98 meters; Power Cord : 01 Load Capacity 2300VA Body Color Black Temperature Operating: 0-45 °C, Storage Temperature:-25 – 65 °C Relative Humidity 0-95 % Approvals cUL Listed, CE, GOST, Queensland Australia, UL Listed, VDE Feature 01 Toolless Rack Mounting Capabilities: Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.” Feature 02 Vertical Mounting Capabilities: Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures. Feature 03 Low Cost Power Distribution: Provides a number of outlets to bring power to rack equipment at an affordable price. Feature 04 Agility: Allows additional run time to be quickly added as needed. Feature 05 Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. Feature 06 Rack-Mountable: Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most-in the racks near the equipment. Feature 07 Single input power source: Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. Weight 2.0 KG Warranty 1 Year -
APC Basic Rack PDU
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Product Type Racl PDU Brand APC Shipping Dimension Weight:5.77KG, Height: 2134mm,213.4CM,Width: 152mm, 15.2CM, Depth: 127mm,12.7CM Input Connection IEC 309 16A 2P+E Input Voltage Nominal: 200V , 208V , 230V Output Voltage Nominal : 230V; Total Current Draw: 16 (Max.) Frequency Input: 50/60 Hz; Load Capacity Cord: 0.91meters; Power Cords: 1, Capacity: 3680VA; Input Current: 16A Component Measurements Height: 1619mm , 161.9CM (Max.),Width: 56mm , 5.6CM (Max.),Depth: 44mm , 4.4CM (Max.) Environment Operating Temperature:0 – 45 °C, Operating Relative Humidity: 5 – 95 %, Operating Elevation: 0-3000meters, Storage Temperature: -25 – 65 °C, Storage Relative Humidity: 5 – 95 %, Storage Elevation: 0-15000meters Approvals CE, GOST, IRAM, VDE Body Color Black Weight 4.86KG 35,000.00৳